DS200DCFBG2B GE

Reliance Electric DDS-SABS5, 32416, 32416-005A (NEW)
NIB Reliance Electric 375 Watt Power Supply 0-57493
RELIANCE ELECTRIC RECTIFIER STACK 86466-74R
Reliance Electric Rectifier Stack 86466-74RB
RELIANCE ELECTRIC RECTIFIER STACK 86466-74RB
RELIANCE ELECTRIC RECTIFIER STACK 86466-87T
0-51864-2 RELIANCE PRINTED CIRCUIT
FS Reliance AutoMax 6011 Processor 57C431B 57C431
Reliance 61C346/61C-346 BRAND
Reliance Electric 45C201 Remote I/O processor NEW NIB
Reliance Electric 57430-1C/574301?C/57430/0-57430?-1C NEW
**NIB** Reliance Electric Rectifier Stack 86466-88R
Reliance Electric 0-51381-10/0513?8110 SCRF Card
RELIANCE ELECTRIC 0-52859-2 DRIVE BOARD 0528592 NIB
RELIANCE ELECTRIC RECTIFIER STACK 86466-87R
RELIANCE ELECTRIC RECTIFIER STACK 86466-88R
RELIANCE ELECTRIC 2GU41003 GP-2000 2GU41 NEW
RELIANCE ELECTRIC 418285-113A PSBD-4A CONTROL BOARD NEW
RELIANCE ELECTRIC 418283-81A TRBD-1 CONTROL BOARD NEW
RELIANCE ELECTRIC 418285-112A VCRB-1A CONTROL BOARD NEW
Reliance Electric AutoMax 57407 4J 574074J Processo NIB
Reliance AutoMate Analog Output 45C360
Reliance Electric 57406-E NEW NIB Drive Controller
Reliance Electric 57C410/57C-410/?0-57C410

分类:
购买咨询热线:15340667322
邮箱:3395949709@qq.com

Description

定子绕组匝间短路故障的判断

定子绕组匝间短路故障,一般是通过测量三相绕组的直流电阻来判断的。但容量较大的电机定子绕组直流电阻很小,加上仪表精度及测量误差等关系的影响,不易得出正确的判断,但可以采用如下办法来判断。

不分解电机,用一台容量适当的单相自耦调压器,从零开始逐步升压,向其中一相通入低压交流电。同时,用一只钳形电流表测量电流,使电流上升到电机额定电流的1/3左右。然后停止升压,用万用表分别测量其它两相感应电压,如果某一相有匝间短路故障,它的感应电压就比另一相低。然后调换一相通电,用同样的方法测量其它两相的感应电压。根据感应电压是否相同,可判断出是否有匝间短路故障。定子匝间短路故障,在维修中一般需要更换电机绕组。

四、鼠笼条断条的判断

笼型转子断条后,一般是空载运行正常,但一加上负载,电机转速就降低,定子电流增大,电机振动,温度增高,并且会伴有不正常的噪声。负荷愈大,断条愈多,上述现象愈严重。

判断是否断条的方法如下:

1、通电法:用一台容量适当的单相调压器,向电机一相绕组通入低压交流电。调压器从零开始慢慢升压,同时用钳形电流表测量电流,使电流上升到电机额定电流的1/2左右时,停止升压。然后用手慢慢转动电动机的转轴,观察钳形电流表的指针。如果指针不动或微微摆动,表明转子完好,如果指针周期性摆动,而且摆动幅度较大,则表明转子鼠笼条有断条故障。

 

Reliance Electric DDS-SABS5, 32416, 32416-005A (NEW)
NIB Reliance Electric 375 Watt Power Supply 0-57493
RELIANCE ELECTRIC RECTIFIER STACK 86466-74R
Reliance Electric Rectifier Stack 86466-74RB
RELIANCE ELECTRIC RECTIFIER STACK 86466-74RB
RELIANCE ELECTRIC RECTIFIER STACK 86466-87T
0-51864-2 RELIANCE PRINTED CIRCUIT
FS Reliance AutoMax 6011 Processor 57C431B 57C431
Reliance 61C346/61C-346 BRAND
Reliance Electric 45C201 Remote I/O processor NEW NIB
Reliance Electric 57430-1C/574301?C/57430/0-57430?-1C NEW
**NIB** Reliance Electric Rectifier Stack 86466-88R
Reliance Electric 0-51381-10/0513?8110 SCRF Card
RELIANCE ELECTRIC 0-52859-2 DRIVE BOARD 0528592 NIB
RELIANCE ELECTRIC RECTIFIER STACK 86466-87R
RELIANCE ELECTRIC RECTIFIER STACK 86466-88R
RELIANCE ELECTRIC 2GU41003 GP-2000 2GU41 NEW
RELIANCE ELECTRIC 418285-113A PSBD-4A CONTROL BOARD NEW
RELIANCE ELECTRIC 418283-81A TRBD-1 CONTROL BOARD NEW
RELIANCE ELECTRIC 418285-112A VCRB-1A CONTROL BOARD NEW
Reliance Electric AutoMax 57407 4J 574074J Processo NIB
Reliance AutoMate Analog Output 45C360
Reliance Electric 57406-E NEW NIB Drive Controller
Reliance Electric 57C410/57C-410/?0-57C410

选择山西润盛 售后无忧
产品质量过硬
只与行业一线品牌的厂家合作
进口/产品齐全
售前服务周到
多次与客户沟通产品型号 质量 价格 货期
与客户共同指定最佳方案
提前解决用户顾虑

业务执行到位
订购产品按时交付
制定完善交货方案,确保工期
协助用户办理验收手续

售后服务完善
质保期内出现问题只换不修
遇到问题绝不推诿扯皮
服务热线7 x 24小时服务 15340667322
邮箱:3395949709@qq.com
网址:www.sxdcs.com

郑重承诺
1.凡本公司出售的物品,模块卡件等,质保期内正常使用出现的质量问题免费换新,绝不推诿扯皮。
2.超出质保期的未停产物资设备,出现质量问题仅收取相关配件成本费用。
3.已停产的物资设备,提供代替型号及设备更换流程服务。
4.客户已购买的物资设备,终生免费升级系统软件,相关技术资料免费提供。
5.不定时回访客户所购物资使用情况,如有问题及时解决。
6.公司热线24小时提供服务,客户提出的问题1小时内做出答复。
7.未尽事宜,公司本着”服务周到、负责到底”的态度,从客户的角度出发实实在在解决问题,以认真严谨的企业作风,竭诚为每一位客户服务。